Non Domestic EPC Conventions Iss.8

  • Convention 2.09 - Acceptable Evidence for High Frequency T8 Lamps

    T8 fluorescent lighting can be operated at either low or high frequency and this control option forms part ofthe SBEM data collection and building performance assessment process. Flicker on the view s...

  • Convention 2.10 - Electric showers in rooms with another source of DHW

    Where an electric shower is present and there is another DHW source (other than instantaneous electricwhich would be treated as the same system) this should be entered as a bivalent system. The other ...

  • Convention 3.01 - Light Pipes

    The modelling of light pipes using SBEM will only be considered where the pipes do not pass through acomplete building storey in order to serve the storey below; in these circumstances consideration s...

  • Convention 3.02 - Adjacency Assumed - Party Walls

    Unless evidence to the contrary is readily and easily available, all buildings adjoining that building or partbuilding which is being assessed, are assumed to be conditioned unless they are of Plannin...

  • Convention 3.03 - Frame Factors

    The ‘Frame Factor’ for windows and roof lights within SBEM defaults to a value of 0.1 (10%). The assessormust always establish the frame factor of an actual window or roof light and replace the SBEM d...

  • Convention 3.07 - Appropriate Use of U and Km Values

    In the absence of more specific values the library (or inference) U and Km values for the fabric constructiontype are used. If an accurate U value or an accurate Km value is available for the specific...

  • Convention 3.08 - Strongly Ventialted Spaces

    Where ventilation specifications are available, strongly ventilated spaces shall be defined as such inaccordance with the table below: Option Brief Description Exterior For an envelope separating the ...

  • Convention 3.09 - Transparent Curtain Walling

    The description of ‘curtain walling’ in the SBEM database refers to solid or opaque wall construction only andtherefore the U and Km values applied to this construction type do not include areas of gl...

  • Convention 3.10 - Appropriate Activity Selection for Animals Housed Overnight

    Except where specific factors require otherwise (evidence will be required): 1. For buildings such as kennels or catteries where the main purpose is housing animals, the overallbuilding type should be...

  • Convention 3.11 - Secondary Glazing

    Where secondary glazing is present in existing buildings, select from the Project database Library thefollowing option:- Acoustic double glazing with 200mm interpane gap. The frame type shall be the f...